Measurement of Copper Vapors in Water-Argon Thermal Plasma Jet

Authors

  • A. Mašláni
  • V. Sember
  • M. Hrabovský

Keywords:

DC arc, plasma jet, copper atoms, excitation temperature

Abstract

Plasma jet generated by water-argon plasma torch is enriched by copper evaporated from the anode sur-face. In this contribution we present results of measurement of emission spectral lines of neutral copper along the jet. We are able to monitor presence of copper vapors in the jet and in addition we use copper lines to obtain excitation temperature. This temperature seems to represent kinetic temperature of turbu-lent downstream regions of the jet with good accuracy.

References

Franke St, Methling R, Uhrlandt D, Bianchetti R, Gati R, Schwinne M, J Phys D Appl Phys 47 (2014) 015202.

Veklich A, Lebid A, Tmenova T, Boretskij V, In: Proceedings of 31st ICPIG, Granada, Spain, (2013).

Rouffet M E, Wendt M, Goett G, Kozakov R, Schoepp H, Weltmann K D, Uhrlandt D, J Phys D Appl Phys 43 (2010) 434003.

Iwata M, Tanaka S, Ikeda K, Goda Y, J Phys D Appl Phys 34 (2010) 3036-3042.

Cressault Y, Hannachi R, Teulet Ph, Gleizes A, Gonnet J-P, Battandier J-Y, Plasma Sources Sci Technol 17 (2008) 035016.

Aubrecht V, Bartlova M, Coufal O, J Phys D Appl Phys 43 (2010) 434007.

Hrabovský M, Pure Appl Chem 74 (2002) 429-433.

Hrabovský M, Kopecký V, Sember V, Kavka T, Chumak O, Konrád M, IEEE Transactions on Plasma Science 34 (2006) 1566-1575.

Sember V, Mašláni A, High Temp Mater P-US 13 (2009) 217 – 228.

Mašláni A, Sember V, Journal of Spectroscopy, vol. 2014, Article ID 952138, 6 pages, (2014). doi:10.1155/2014/952138.

Downloads

Published

2015-04-06

Issue

Section

Articles