Experimental Study of Arc Erosion in Gas-blasting and Free-burning Conditions in High-voltage Circuit Breakers

Authors

  • Y. Zhou Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, U. K.
  • J. Humphries Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, U. K.
  • J. Spencer Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, U. K.
  • J. Yan Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, U. K.

DOI:

https://doi.org/10.14311/ppt.2023.1.32

Keywords:

arc erosion, gas-blasting, free-burning, mass loss

Abstract

Arc erosion behavior depends on varieties of factors, such as the shape and material of contacts, the gas type and the pressure filled in the chamber. In this contribution, experimental research on the gas-blasting and free-burning conditions was carried out in a model circuit breaker to investigate the gas blowing effect on the mass loss of arcing contacts. SF6 was filled in the chamber and copper-tungsten was used as the contact material. Three different peak current amplitudes (5/20/35kA) were selected, and the average mass loss of plug contact was measured after five consecutive arcing tests. The erosion physical process between arc root and contact material is extremely complex. The mass loss was estimated with four different indexes, which include integral of current squared, thermal stress, transferred electric charge and arc energy. It has been found that the arc energy can be used to represent the degree of arc erosion to relate the gas-blasting and free-burning conditions.

References

Z. Wang. Study on the Mechanisms and Prediction Methods of Arcing Contact Erosion of High-Voltage SF6 Circuit Breaker. The University of Liverpool (United Kingdom), 2018. doi:10.17638/03026544.

J. Tepper, M. Seeger, T. Votteler, et al. Investigation on erosion of Cu/W contacts in high-voltage circuit breakers. IEEE transactions on components and packaging technologies, 29(3):658–665, 2006. doi:10.1109/TCAPT.2006.880476.

Y. Cui, C. Niu, Y. Wu, et al. Experimental study on the transformation of the W70Cu30 anode erosion mode in DC gaseous arcs—better insights into mechanisms of electrode erosion behavior using in situ diagnosis. Journal of Physics D: Applied Physics, 52(47):474001, 2019. doi:10.1088/1361-6463/ab395f.

Y. Cui, Y. Wu, C. Niu, et al. Evolution of anodic erosion components and heat transfer efficiency for W and W80Ag20 in atmospheric-pressure arcs. Journal of Physics D: Applied Physics, 53(47):475203, 2020. doi:10.1088/1361-6463/ababcf.

M. Landry, O. Turcotte, and F. Brikci. A complete strategy for conducting dynamic contact resistance measurements on hv circuit breakers. IEEE Transactions on Power Delivery, 23(2):710–716, 2008. doi:10.1109/TPWRD.2008.917694.

A. C. de Oliveira, E. G. da Costa, A. J. R. Serres, et al. Application of bioinspired antennas in the monitoring of high voltage circuit breakers. IEEE Transactions on Power Delivery, 37(5):4418–4426, 2022. doi:10.1109/TPWRD.2022.3170309.

M. Mohammadhosein, K. Niayesh, A. A. Shayegani-Akmal, and H. Mohseni. Online assessment of contact erosion in high voltage gas circuit breakers based on different physical quantities. IEEE Transactions on Power Delivery, 34(2):580–587, 2018. doi:10.1109/TPWRD.2018.2883208.

A. Muharemovic, M. Kapetanovic, A. Ahmethodzic, and A. Fetahagic. Arcing contacts and nozzle condition diagnostics by means of measure of thermal stresses. In CIGRE Colloquium, Asset Management of Switching Equipment and New Trends in Switching Technologies, pages 118–123, 2003.

M.-H. Kim, K.-H. Kim, A. Smajkic, et al. Influence of contact erosion on the state of SF6 gas in interrupter chambers of HV SF6 circuit breakers. In 2014 IEEE International Power Modulator and High Voltage Conference (IPMHVC), pages 466–469. IEEE, 2014. doi:10.1109/IPMHVC.2014.7287312.

Downloads

Published

2023-08-08

Issue

Section

Articles