Capillary Discharge XUV Radiation Source

Authors

  • M. Nevrkla

DOI:

https://doi.org/10.14311/1123

Keywords:

Capillary discharge, Z-pinch, XUV, soft X-ray, Rogowski coil, pulsed power

Abstract

A device producing Z-pinching plasma as a source of XUV radiation is described. Here a ceramic capacitor bank pulse-charged up to 100 kV is discharged through a pre-ionized gas-filled ceramic tube 3.2 mm in diameter and 21 cm in length. The discharge current has amplitude of 20 kA and a rise-time of 65 ns. The apparatus will serve as experimental device for studying of capillary discharge plasma, for testing X-ray optics elements and for investigating the interaction of water-window radiation with biological samples. After optimization it will be able to produce 46.9 nm laser radiation with collision pumped Ne-like argon ions active medium. 

Downloads

Download data is not yet available.

Author Biography

M. Nevrkla

Downloads

Published

2009-01-02

How to Cite

Nevrkla, M. (2009). Capillary Discharge XUV Radiation Source. Acta Polytechnica, 49(2). https://doi.org/10.14311/1123

Issue

Section

Articles