A simplified design of a concrete sandwich structure containing a reinforcing rib

Authors

  • Jan Macháček Czech Technical University in Prague, Faculty of Civil Engineering, Department of Architectural Engineering, Thákurova 7, 166 29 Prague, Czech Republic
  • Eliška Kafková Czech Technical University in Prague, Faculty of Civil Engineering, Department of Architectural Engineering, Thákurova 7, 166 29 Prague, Czech Republic
  • Věra Kabíčková Czech Technical University in Prague, Faculty of Civil Engineering, Department of Architectural Engineering, Thákurova 7, 166 29 Prague, Czech Republic; Czech Technical University in Prague, University Centre for Energy Efficient Buildings, Třinecká 1024, 273 43 Buštěhrad, Czech Republic
  • Tomáš Vlach Czech Technical University in Prague, Faculty of Civil Engineering, Department of Architectural Engineering, Thákurova 7, 166 29 Prague, Czech Republic; Czech Technical University in Prague, University Centre for Energy Efficient Buildings, Třinecká 1024, 273 43 Buštěhrad, Czech Republic

DOI:

https://doi.org/10.14311/APP.2024.49.0055

Keywords:

high performance concrete, precast concrete, sandwich panels, composite reinforcement, shear reinforcement, rigid heat insulation, strut-and-tie model

Abstract

This article presents the use of a strut and tie analogy for modelling the behaviour of a concrete sandwich structure, which is formed by thin outer concrete layers made of high-performance concrete and reinforcing ribs. The beams transmitting shear are made of a rigid material with low thermal conductivity (Purenit) in combination with a carbon fibre reinforced polymer. The purpose of these ribs is to ensure reliable shear interaction of the outer concrete layers regardless of the thermal insulation of the sandwich structure. A simplified model using the truss analogy in the Scia Engineer software was used for the design of this structure. Furthermore, this design was verified experimentally on a section of the sandwich panel where the feasibility and functionality were tested by a four-point bending test. Finally, the theoretical values from the model were compared with the experimental results. This also includes a simple evaluation of whether this simplified modelling of the structure’s behaviour is appropriate. The paper contains a summary of the conditions that could have affected the results.

Downloads

Download data is not yet available.

Downloads

Published

2024-11-21

How to Cite

A simplified design of a concrete sandwich structure containing a reinforcing rib. (2024). Acta Polytechnica CTU Proceedings, 49, 55-59. https://doi.org/10.14311/APP.2024.49.0055