DIAMOND DETECTORS FOR FAST TRANSIENT SCRAM MEASUREMENTS – THE DETECTOR DEVELOPMENT
DOI:
https://doi.org/10.14311/APP.2019.24.0021Keywords:
Diamond detector, neutron detection, nuclear reactor, pulse shape analysis, boron conversion, fast transient, SCRAM, VR-1 reactor.Abstract
This paper presents a development of special diamond detector for time dependent neutron flux measurements in a nuclear reactor. Neutron flux changes during SCRAM are difficult to measure by existing detector technologies. Therefore, a new detector is developed. This new type diamond based detector should allow to perform fast measurements of neutron flux during SCRAM with high pulse count rate. The diamond detector design and signal processing are described in this paper including the pulse shape discrimination method. In addition to theoretical detector study, three detector was manufactured at CEA Saclay. Experience gathered during manufacturing is described as well.Downloads
Download data is not yet available.
Downloads
Published
2019-12-06
Issue
Section
Articles
How to Cite
DIAMOND DETECTORS FOR FAST TRANSIENT SCRAM MEASUREMENTS – THE DETECTOR DEVELOPMENT. (2019). Acta Polytechnica CTU Proceedings, 24. https://doi.org/10.14311/APP.2019.24.0021