HEAT TRANSFER MODELLING OF TWO-PHASE FLOW IN ISOLATED CHANNEL

Authors

  • Daniel Vlček KJR FJFI CVUT, V Holešovickách 2, Praha 8, Czech Republic
  • Vojtěch Caha KJR FJFI CVUT, V Holešovickách 2, Praha 8, Czech Republic
  • Martin Ševeček KJR FJFI CVUT, V Holešovickách 2, Praha 8, Czech Republic

DOI:

https://doi.org/10.14311/APP.2018.14.0049

Keywords:

Post-CHF, Heat transfer, Modelling and Simulation, Two-phase Flow, Correlations, Experimental data

Abstract

This paper deals with Post-CHF (critical heat flux) heat transfer with the focus on different regimes of film boiling. The new thermal-hydraulic code TUBE 2.0 is presented. This code uses the equation of energy conservation and predefined correlations to establish wall temperature, the departure of nucleate boiling ratio as well as other parameters of cooling in a simple geometry - an isolated channel. With experimental data of inverted annular film boiling from Stewart, the best-performing correlation for calculation of post-CHF heat transfer in the channel was determined. Finally, the new presented code TUBE 2.0 and subchannel code SUBCAL owned by Chemcomex a.s. are compared using results of various experiments conducted by Becker. Data from Stewart could not be used because of inability to predict the onset of boiling crisis with several correlations.

Downloads

Download data is not yet available.

Downloads

Published

2018-05-17

Issue

Section

Articles

How to Cite

HEAT TRANSFER MODELLING OF TWO-PHASE FLOW IN ISOLATED CHANNEL. (2018). Acta Polytechnica CTU Proceedings, 14, 49-55. https://doi.org/10.14311/APP.2018.14.0049