Recycled materials for sublayers

Authors

  • Richard Svoboda Brno University of Technology, Faculty of Civil Engineering, Veveří 331/95, 602 00 Brno, Czech Republic
  • Dana Hubáčková Brno University of Technology, Faculty of Civil Engineering, Veveří 331/95, 602 00 Brno, Czech Republic
  • Jan Valehrach Brno University of Technology, Faculty of Civil Engineering, Veveří 331/95, 602 00 Brno, Czech Republic

DOI:

https://doi.org/10.14311/APP.2023.43.0111

Keywords:

recycled construction materials, concrete recyclate, sieve analysis, optimum moisture, California bearing ratio, static plate load test

Abstract

The article focuses on the recycled materials used in sleeper substructure. In the introduction, it summarizes the requirements for bearing layers of railway substructure and recycling of waste construction materials. The article presents the materials on which laboratory tests have been carried out and discusses in detail the most perspective – recycled concrete. For concrete recyclate, the article describes the results of laboratory tests – sieve analysis, determination of optimum moisture, and determination of bearing capacity using California bearing ratio, Immediate bearing index and Static deformation modulus.

Downloads

Download data is not yet available.

Downloads

Published

2023-11-22

How to Cite

Recycled materials for sublayers. (2023). Acta Polytechnica CTU Proceedings, 43, 111-116. https://doi.org/10.14311/APP.2023.43.0111