LEKSELL GAMMA KNIFE - PAST, PRESENT AND FUTURE
Keywords:
Leksell Gamma Knife, stereotactic radiosurgery, radiation oncologyAbstract
The first prototype of the Leksell Gamma Knife was installed in 1968 at Sophiahemmet Hospital in Stockholm, Sweden. Since that this system underwent significant improvement affecting quality and safety of patient’s treatment. Initial Leksell Gamma Knife systems called U and B were later on replaced by models C and 4C. Finally, the newest system called Leksell Gamma Knife Perfexion was introduced in 2006. The first and currently only gamma knife unit in the Czech Republic was installed in Prague in 1992. Initial Leksell Gamma Knife model B was later upgraded to the Leksell Gamma Knife model C which was finally replaced by the latest Leksell Gamma Knife Perfexion installed at Na Homolce Hospital in December 2009. The source of radiation in the Leksell Gamma Knife is 60Co. Half life of 60Co is 5.26 years. Two energies of gamma photons are emitted with energy of 1.17 MeV and 1.33 MeV. High number of multiple 60Co beams directed in one focus point are used. This geometry leads to a high dose in focus point and very low dose to surrounding tissue. There are 201 60Co beams in the case of Leksell Gamma Knife models U, B, C and 4C and 192 60Co beams in the case of Perfexion, respectively. Radiosurgical treatment is done in one single fraction. Leksell stereotactic frame which is attached to patient’s head is used for exact imaging and targeting. The whole procedure involves typically only one single fraction of radiation and is done in one treatment day. Main diagnosis involve following intracranial lesions: arteriovenous malformations, meningiomas, acoustic neuromas, pituitary adenomas, single and multiple metastasis, glial tumors and functional radiosurgery such as trigeminal neuralgia. This review article describes how this system evolved since the first prototype, provides technical specifications of different Leksell Gamma Knife systems and makes comparison between different systems.Downloads
Published
Issue
Section
License
Copyright (c) 2017 Josef Novotný
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of the first publication with the work simultaneously licensed under a Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) that allows others to share the work with an acknowledgment of the work's authorship and initial publication in CTJ.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal’s published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website or ResearchGate) prior to and during the submission process, as it can lead to productive exchanges.
CTJ requires that all of the content of the manuscript has been created by its respective authors or that permission to use a copyrighted material has been obtained by the authors before submitting the manuscript to CTJ. CTJ requires that authors have not used any copyrighted material illegally, as for example a picture from another journal or book, a photo, etc. It is the author’s responsibility to use only materials not violating the copyright law. When in doubt, CTJ may ask the authors to supply the pertinent permission or agreement about the use of a copyrighted material.
The opinions expressed in CTJ articles are those of authors and do not necessarily reflect the views of the publishers or the Czech Society for Biomedical Engineering and Medical Informatics.