Apparatus for monitoring the propagation of gases from avalanche victims in simulated avalanche snow and its validation
DOI:
https://doi.org/10.14311/CTJ.2026.56.07Abstract
Complete avalanche burial leads to the progressive development of hypoxia and hypercapnia, the course of which depends, among other factors, on the transport of respiratory gases between the air pocket and the surrounding snow. Previous experimental studies have focused primarily on the physiologic response of buried individuals or on gas concentrations within the air pocket, whereas the temporal evolution of their spatial distribution in the surrounding snow has not been adequately described. The aim of this study was to design, construct, and experimentally validate an apparatus for measuring spatial O2 and CO2 concentration profiles in simulated avalanche snow while a participant breathes into a central air pocket. The apparatus consists of a three-dimensional frame, a dual-limb breathing circuit, five radially oriented sampling-needle racks carrying a total of 45 sampling needles, and a pneumatic system for parallel collection and temporary storage of samples. In each measured direction, samples can be collected simultaneously from nine locations spaced at 50-mm intervals. The sample-and-hold system enables subsequent sequential analysis of the samples using a single respiratory gas analyzer. The performance of the apparatus was evaluated in four validation tests conducted with natural snow in a mountain environment. Under the conditions of these tests, neither active sampling from adjacent needles nor sampling from the monitored needle had a detectable effect on the measured O2 and CO2 concentrations. No systematic deviation in the concentration profiles attributable to preferential gas transport along the breathing circuit or the sampling needles was observed. Time-dependent changes in sample composition during storage in polymer tubing were experimentally characterized and compensated for using an empirical correction function. The proposed apparatus enables reproducible monitoring of the temporal evolution of the spatial distribution of respiratory gases in simulated avalanche snow.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Ladislav Bís, Václav Ort, Karel Roubik

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of the first publication with the work simultaneously licensed under a Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) that allows others to share the work with an acknowledgment of the work's authorship and initial publication in CTJ.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal’s published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website or ResearchGate) prior to and during the submission process, as it can lead to productive exchanges.
CTJ requires that all of the content of the manuscript has been created by its respective authors or that permission to use a copyrighted material has been obtained by the authors before submitting the manuscript to CTJ. CTJ requires that authors have not used any copyrighted material illegally, as for example a picture from another journal or book, a photo, etc. It is the author’s responsibility to use only materials not violating the copyright law. When in doubt, CTJ may ask the authors to supply the pertinent permission or agreement about the use of a copyrighted material.
The opinions expressed in CTJ articles are those of authors and do not necessarily reflect the views of the publishers or the Czech Society for Biomedical Engineering and Medical Informatics.