Numerical analysis of timber beam exposed to fire
Abstract
In this paper the advanced calculation method to determine the response of timber beams during fire is presented. In the first phase of the advanced calculation method the development of temperature across the cross-section of the beam and the char dept are determined. The second phase consists of the mechanical analysis of timber beam. Char dept for one dimensional charring is compared to the empirical values from the literature. In addition, fire resistance calculated with advanced calculation model is compared with the fire resistance calculated with reduced cross-sectional method proposed by Eurocode (EN 1995-1-2 (2005)).Downloads
Published
Issue
Section
License
Authors who publish with ASFE agree to the following terms:
1. Authors retain copyright and grant the ASFE right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).