Determination of Rheological Parameters from Measurements on a Viscometer with Coaxial Cylinders – Choice of the Reference Radius

Authors

  • F. Rieger

DOI:

https://doi.org/10.14311/892

Keywords:

viscometer with coaxial cylinders, power-law fluids, Bingham plastics

Abstract

Knowledge about rheological behavior is necessary in engineering calculations for equipment used for processing concentrated suspensions and polymers. Power-law and Bingham models are often used for evaluating the experimental data. This paper proposes the reference radius to which experimental results obtained by measurements on a rotational viscometer with coaxial cylinders should be related. 

Downloads

Download data is not yet available.

Author Biography

  • F. Rieger

Downloads

Published

2006-01-06

Issue

Section

Articles