Determination of Rheological Parameters from Measurements on a Viscometer with Coaxial Cylinders – Choice of the Reference Radius

F. Rieger

Abstract


Knowledge about rheological behavior is necessary in engineering calculations for equipment used for processing concentrated suspensions and polymers. Power-law and Bingham models are often used for evaluating the experimental data. This paper proposes the reference radius to which experimental results obtained by measurements on a rotational viscometer with coaxial cylinders should be related. 

Keywords


viscometer with coaxial cylinders; power-law fluids; Bingham plastics

Full Text: PDF

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

ISSN 1210-2709 (Print)
ISSN 1805-2363 (Online)