SEISMIC MITIGATION EFFICIENCY STUDY OF THE COUPLING BEAM DAMPER IN THE SHEAR WALL STRUCTURE

Authors

  • Xin Huang College of Airport, Civil Aviation University of China, Tianjin

DOI:

https://doi.org/10.14311/CEJ.2021.01.0002

Keywords:

Shear wall structure, Coupling beam damper, Earthquake action, Seismic mitigation efficiency, Damper optimal layout, Performance parameter of the damper

Abstract

Coupling beam damper can be easily repaired in the post-earthquake, which can dissipate the seismic energy of the structure in the earthquake action. In this paper, the seismic mitigation efficiency of the coupling beam damper in the shear wall structure is analysed by using the fast nonlinear analysis method. Meanwhile, the effect of the layout location and number of the coupling beam dampers on the seismic mitigation efficiency of the structure are studied. Finally, the effect of the performance parameter of the coupling beam damper on the seismic mitigation efficiency is also analysed. The results indicate that: the story shear force and the drift angle of the shear wall structure can be effectively decreased because of the coupling beam damper, and the maximum decreased amplification of the story drift angle and base shear force can reach up to 16.7% and 8.8% respectively. Relating to the decreased amplification of the base shear force, the decreased amplification of the story drift angle of the structure with coupling beam damper is obvious. The coupling beam damper installed in the upper part of the structure is more economical, because the deformation of the structural coupling beam is mainly concentrated in the upper part of the structure. To ensure economic of the structure with damper, the reasonable coupling damper performance parameter should be determinate according to the dynamic response of the shear wall structure in the earthquake action. The above research work can provide guidance for the seismic design of the shear wall structure.

Downloads

Download data is not yet available.

References

Jarrahi H, Asadi A, Khatibinia M, Etedali S. Optimal design of the rotational friction dampers for improving seismic performance of inelastic structures. Journal of Building Engineering, 2020, 27: 100960.

Xu L H, Xie X S, Li Z X. Development and experimental study of a self-centering variable damping energy dissipation brace. Engineering Structures, 2018;160:270-280.

Gong S M, Zhou Y, Ge P. Seismic analysis for tall and irregular temple buildings: A case study of strong nonlinear viscoelastic dampers. Structural design of tall and special building, 2017;26:e1352.

Cai WH, Yu B J, Kaewunruen S. Shaking Table Tests of Suspended Structures Equipped with Viscous Dampers. Applied Sciences, 2019,9, 2616; doi:10.3390/app9132616.

Kim H S, Kang J W. Smart outrigger damper system for response reduction of tall building subjected to wind and seismic excitations. International journal of steel structures, 2017;17(4):1263-1272.

Lin P C, Takeuchi T, Matsui R. Seismic performance evaluation of single damped-outrigger system incorporating buckling-restrained braces. Earthquake engineering and structural dynamics, 2018;47:2343-2365.

Wang Qi,Gan Gang. Calculation of effective additional damping ratio of energy dissipation structure based on linear equivalent method. Journal of Building Structures, 2012, 33(11): 46-52(in chinese).

Jiang Q, Wang H Q, Feng Y L et.al. Seismic performance analysis of a damage-controlling RC frame with damping cladding panels. Engineering mechanics, 2019, 36(10): 144-151(in chinese).

De Domenicoa D, Ricciardia G, Takewakib I. Design strategies of viscous dampers for seismic protection of building structures: A review. Soil dynamics and earthquake engineering, 2019, 118: 144-165.

Shi S, Du D S, Wang S G et.al. Assessment of reinforcement scheme for a high-rise steel structure based on seismic resilience and reinforcement benefit ratio. China civil engineering journal, 2019, 52(11): 1-11(in chinese).

Zhang Z, Ou J P, Li D S, Zhang S F. Optimization Design of Coupling Beam Metal Damper in Shear Wall Structures. Applied Sciences, 2017,7, 137; doi:10.3390/app7020137.

Wang T, Yang F L, Wang X, Cui Y. Experimental Study on a Hybrid Coupling Beam With a Friction Damper Using Semi-steel Material. Frontiers in Materials, 2019, 6, doi:10.3389/frmats.2019.00135.

Renee M L, Constantin C, Michael M. Viscoelastic coupling dampers for the enhanced multiple seismic hazard level performance of high-rise buildings. Earthquake Spectra, 2018, 34(4): 1847-1867.

Chinese version of the ETABS.2004. Beijing Golden civil software technology company and China architecture standard design and Research, China Architecture and Building Press: Beijing, China (in Chinese).

Code for seismic design of buildings (GB50011-2016). 2016. China Ministry of Construction, China Architecture and Building Press: Beijing, China (in Chinese).

Downloads

Published

2021-04-09

How to Cite

Huang, X. (2021). SEISMIC MITIGATION EFFICIENCY STUDY OF THE COUPLING BEAM DAMPER IN THE SHEAR WALL STRUCTURE. Stavební Obzor - Civil Engineering Journal, 30(1). https://doi.org/10.14311/CEJ.2021.01.0002

Issue

Section

Articles