COMPARATIVE ANALYSIS OF SPATIAL STRESS IN THE JOINT ZONE OF TOWER PIER UNDER DIFFERENT SYSTEMS OF CABLE-STAYED BRIDGE

Authors

  • Long Liu Anyang Institute of Technology
  • Yingying Bi Anyang Institute

DOI:

https://doi.org/10.14311/CEJ.2021.03.0054

Keywords:

Cable-stayed bridge, Joint area of tower-beam-pier, Stress analysis, Semi-floating system, Rigid frame system, Tower-beam consolidation system

Abstract

To explore the stress of the tower-beam-pier joint zone of a cable-stayed bridge under different systems, the submodel method in the finite element software ABAQUS was used to establish the local model of the tower-beam-pier joint zone of the bridge. At the same time, Midas/Civil was used to establish the rod system finite element model of the whole bridge. The correctness of the local model was verified by comparing the results of the finite element model and the local model. Then, by changing the combination mode of tower beam pier, the stress comparison analysis of the joint zone of the tower-beam-pier under different systems was carried out. The results showed the stress distribution of the semi-floating system was more reasonable than that of the rigid frame system and the consolidation system. In the use of the three different systems, there was concentrated tensile stress at the chamfer of the web and the bottom plate, where the steel bars should be added. In the rigid frame system, the deflection of the main beam under the load was the smallest, and the maximum displacement occurred at the boundary section, with the value of only 2.668mm.

Downloads

Download data is not yet available.

References

Yu Yanxia, Wang Dezhi. Design of the 95+125 m Asymmetric Single Tower Part Cable-Stayed Bridge of Fuzhou-Xiamen High-speed Railway [J]. Railway Standard Design,2020,64(S1):147-151.

Wen Wangqing, Li Diping, Yan Aiguo, Huang Naxin. Study on Structural System of 3×340m Multi-tower Cable-Stayed Bridge [J]. Railway Standard Design,2020,64(03):86-90.

Pan Xiangwen. Study on Mechanical Properties of High-speed Railway Cable-stayed Bridges with Short Tower [J/OL]. Railway standard design :1-6[2021-03-16]

DENG Jiangtao. Analysis and Verification of Local Stress in Consolidation Section of Low Tower Cable-stayed Bridge Pier and Tower Beam of High-speed Railway [J]. Railway Standard Design,2016,60(06):43-48.

Peiheng Long, Zechao Lu, Suwei Hou, Chiyu Jiao, Guangda Zhang. Research on Stress Analysis of Consolidation Area of Tower Pier of Steel-composite Composite Cable-stayed Bridge [J]. Chinese and Foreign Highway,2018,38(01):80-83.

Yu Lusong, Zhu Dongsheng. Local Stress Analysis of Consolidation Point of Pier of Partly Cable-Stayed Bridge [J]. Bridge Construction, 2008(01):54-57.

Song Jun, Zhou Jianting, Chen Zengshun. Local Analysis of Consolidation Section of Pier of Cable-stayed Bridge Based on Submodel Method [J]. Journal of Chongqing Jiaotong University (Natural Science),2013,32(03):379-384.

HU Yuliu. Model Test Study on Consolidation Zone of Main Bridge Pier of Changmen Bridge [J]. Bridge Construction,2018,48(02):72-76.

Wang Ziwen, Xu Shiwen, Deng Lu, Liu Binghui, Guo Jinlong. Model test on tower-beam bonding zone of variable cross-section elliptic single-tower cable-stayed bridge [J]. Chinese and foreign highway,2019,39(04):83-88.

Shangguan Ping, Fang Zhenzheng, Zhuo Weidong. Journal of Fuzhou University (Natural Science Edition),1999(03):21-24. (in Chinese)

Dai Gonglian, Su Miao. Experimental Research and Numerical Analysis on the Structure of Tower Girder of High-speed Railway Trough-beam Cable-stayed Bridge [J]. Journal of the China Railway Society,2015,37(03):85-92.

ZHOU Min, DAI Gonglian, SU Miao. Numerical Simulation of Stress in Consolidation Zone of Tower Pier of Trough-section Cable-Stayed Bridge [J]. Journal of Railway Science and Engineering,2013,10(04):35-40.

Li Bo, Wang Lifeng, Chen Xinpei, Wang Erqiang. Spatial Stress Analysis of 0~# Block of Short Tower Cable-Stayed Bridge [J]. China Highway and Wai Highway,2014,34(03):127-130.

Jiang Rongfeng. Stress Analysis of Consolidation Zone of Single Tower Cable-stayed Bridge with Channel Section [D]. Central South University,2013. ZENG Ningye. Local Stress Analysis of Tower Beam Pier Consolidation Section of Long-span Rail Transit Cable-stayed Bridge [D]. Southwest Jiaotong University,2012.