SENSITIVITY ANALYSIS OF BUILDING STRUCTURES WITHIN THE SCOPE OF ENERGY, ENVIRONMENT AND INVESTMENT

Authors

  • František Kulhánek Czech Technical University, Faculty of Civil Engineering, Building Structures Department, Prague, Thákurova 7, 166 29 Praha 6, Czech Republic
  • Kağan Poyraz Czech Technical University, Faculty of Civil Engineering, Building Structures Department, Prague, Thákurova 7, 166 29 Praha 6, Czech Republic

DOI:

https://doi.org/10.14311/CEJ.2015.03.0017

Keywords:

Sensitivity analysis, sustainable design, multi-criteria assessment, envelope structure

Abstract

The primary objective of this paper is to prove the feasibility of sensitivity analysis with dominant weight method for structure parts of envelope of buildings inclusive of energy; ecological and financial assessments, and determination of different designs for same structural part via multi-criteria assessment with theoretical example designs ancillary.
Multi-criteria assessment (MCA) of different structural designs or in other word alternatives aims to find the best available alternative. The application of sensitivity analysis technique in this paper bases on dominant weighting method. In this research, to choose the best thermal insulation design in the case of that more than one projection, simultaneously, criteria of total thickness (T); heat transfer coefficient (U) through the cross section; global warming potential (GWP); acid produce (AP); primary energy content (PEI) non renewable and cost per m2 (C) are investigated for all designs via sensitivity analysis. Three different designs for external wall (over soil) which are convenient with regard to globally suggested energy features for passive house design are investigated through the mentioned six projections. By creating a given set of scenarios; depending upon the importance of each criterion, sensitivity analysis is distributed.
As conclusion, uncertainty in the output of model is attributed to different sources in the model input. In this manner, determination of the best available design is achieved. The original outlook and the outlook afterwards the sensitivity analysis are visualized, that enables easily to choose the optimum design within the scope of verified components.

Downloads

Download data is not yet available.

References

POYRAZ, Kağan. Buildings with Low Energy Consumption for the Republic of Turkey. Prague, 2015. Doctorate Dissertation. Czech Technical University in Prague. Vedoucí práce Doc.Ing. František Kulhánek, CSc.

MultiCriteria Analysis. Center for International Forestry Research: Local People, Devolution & Adaptive Collaborative Management Programme [online]. 2009 [cit. 2015-07-30]. Dostupné z: http://www.cifor.org/acm/methods/mca.html

HÁJEK, Petr. Optimalizace a multikriteriální hodnocení funkční způsobilosti pozemních staveb: D24FZS2011. Prague, 2014. Lecture. Czech Technical University in Prague

AUSTRIAN INSTITUTE FOR HEALTHY AND ECOLOGICAL BUILDING (IBO). Details for Passive Houses - A Catalogue of Ecologically Rated Constructions. Vienna: SpringerWienNewYork, 2007. ISBN 978-3-211-29763-6.

MINISTRY OF ENVIRONMENT AND URBAN PLANNING OF THE REPUBLIC OF TURKEY. 2013 Yılı İnşaat ve Tesisat Birim Fiyatları. Ankara: İller Bankası, 2013. ISBN 978-1-111-16209-2.

Wandelemente aus Holzspanbeton; Thermo-span IW 20/13 Innenwandsteine. Baubook: Ökologische Bauprodukte [online]. [cit. 2014-01-22]. Dostupné z: http://www.baubook.info/index.php

MaliyetAnaliz [online]. 2014 [cit. 2014-01-04]. Dostupné z: http://www.maliyetanaliz.com

ODE Yalıtım Insulates the Future [online]. 2013 [cit. 2013-01-09]. Dostupné z: http://www.ode.com.tr

Tunç Pazarlama [online]. 2014 [cit. 2014-01-05]. Dostupné z: http://www.tuncpazarlama.com

Dinamik Isı A.Ş. [online]. 2014 [cit. 2014-01-05]. Dostupné z: http://www.dinamik-izmir.com

İsolion Isı Yalıtım Sistemleri ve Kimyasalları [online]. 2014 [cit. 2014-01-06]. Dostupné z: http://www.isolion.com.tr

İsolion Isı Yalıtım Sistemleri ve Kimyasalları [online]. 2014 [cit. 2014-01-06]. Dostupné z: http://www.isolion.com.tr

Isover Saint – Gobain, Isover - the widest range of thermal, acoustic, and fire insulation [online]. 2014 [cit. 2014-01-05]. Dostupné z: http://www.isover.cz/en

İzocam the Name of Insulation in Turkey [online]. 2014 [cit. 2014-01-02]. Dostupné z: http://www.izocam.com.tr

Ankarapor [online]. 2014 [cit. 2014-01-04]. Dostupné z: http://www.ankapor.com

CZECH REPUBLIC. Tepelná Ochrana Budov - Část 2 Požadavky (Thermal Protection of Buildings - Part 2: Requirements). In: Česká Technická Norma. Czech Republic: Úřad Pro Technickou Normalizaci, Netrologii a Státní Zkušebnictví, 2011

Downloads

Published

2015-10-31

How to Cite

Kulhánek, F., & Poyraz, K. (2015). SENSITIVITY ANALYSIS OF BUILDING STRUCTURES WITHIN THE SCOPE OF ENERGY, ENVIRONMENT AND INVESTMENT. Stavební Obzor - Civil Engineering Journal, 24(3). https://doi.org/10.14311/CEJ.2015.03.0017

Issue

Section

Articles